Energy Performance Certificate

21, Anderson Road, B66 4AR

EPC Report

Energy rating

Current: 1 G | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 13 | Potential: 67
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 13 Current: 13 67 Potential: 67
Field Value
LMK KEY 0883-2876-6350-9195-3495
ADDRESS1 21, Anderson Road
ADDRESS2
ADDRESS3
POSTCODE B66 4AR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Enclosed Mid-Terrace
INSPECTION DATE 2015-05-16
LOCAL AUTHORITY E08000028
CONSTITUENCY E14001478
COUNTY
LODGEMENT DATE 2015-05-17
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 13
ENVIRONMENT IMPACT POTENTIAL 67
ENERGY CONSUMPTION CURRENT 745
ENERGY CONSUMPTION POTENTIAL 186
CO2 EMISSIONS CURRENT 15
CO2 EMISS CURR PER FLOOR AREA 126
CO2 EMISSIONS POTENTIAL 3.9
LIGHTING COST CURRENT 110
LIGHTING COST POTENTIAL 112
HEATING COST CURRENT 3580
HEATING COST POTENTIAL 881
HOT WATER COST CURRENT 529
HOT WATER COST POTENTIAL 80
TOTAL FLOOR AREA 117
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 1
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 1
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION No system present: electric immersion assumed
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.69
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 21, Anderson Road
LOCAL AUTHORITY LABEL Sandwell
CONSTITUENCY LABEL Smethwick
POSTTOWN SMETHWICK
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2015-05-17 15:09:27
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 3
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 32142925
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000005
Address display
Nation ew