Energy Performance Certificate

9, School Lane, Addingham, LS29 0JF

EPC Report

Energy rating

Current: 59 D | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 51 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 Current: 51 63 Potential: 63
Field Value
LMK KEY 0868-3972-7262-6518-8910
ADDRESS1 9, School Lane
ADDRESS2 Addingham
ADDRESS3
POSTCODE LS29 0JF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-12-06
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001308
COUNTY
LODGEMENT DATE 2018-12-06
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 51
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 288
ENERGY CONSUMPTION POTENTIAL 214
CO2 EMISSIONS CURRENT 6.4
CO2 EMISS CURR PER FLOOR AREA 52
CO2 EMISSIONS POTENTIAL 4.8
LIGHTING COST CURRENT 86
LIGHTING COST POTENTIAL 86
HEATING COST CURRENT 1134
HEATING COST POTENTIAL 1036
HOT WATER COST CURRENT 105
HOT WATER COST POTENTIAL 73
TOTAL FLOOR AREA 123
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 89
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 89% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.33
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, School Lane, Addingham
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Keighley and Ilkley
POSTTOWN ILKLEY
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2018-12-06 19:26:38
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 19
LOW ENERGY FIXED LIGHT COUNT 17
UPRN 100051248362
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000003
Address display
Nation ew