Energy Performance Certificate
240, Newington Road, CT12 6QD
Energy rating
Current: 59 D | Potential: 86 B
Environmental impact (CO₂)
Current: 54
| Potential: 85
| Field | Value |
|---|---|
| LMK KEY | 0868-2840-7663-9991-0735 |
| ADDRESS1 | 240, Newington Road |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | CT12 6QD |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 59 |
| POTENTIAL ENERGY EFFICIENCY | 86 |
| PROPERTY TYPE | House |
| BUILT FORM | End-Terrace |
| INSPECTION DATE | 2019-06-10 |
| LOCAL AUTHORITY | E07000114 |
| CONSTITUENCY | E14001216 |
| COUNTY | — |
| LODGEMENT DATE | 2019-06-10 |
| TRANSACTION TYPE | Rental |
| ENVIRONMENT IMPACT CURRENT | 54 |
| ENVIRONMENT IMPACT POTENTIAL | 85 |
| ENERGY CONSUMPTION CURRENT | 303 |
| ENERGY CONSUMPTION POTENTIAL | 77 |
| CO2 EMISSIONS CURRENT | 3.7 |
| CO2 EMISS CURR PER FLOOR AREA | 55 |
| CO2 EMISSIONS POTENTIAL | 1.0 |
| LIGHTING COST CURRENT | 85 |
| LIGHTING COST POTENTIAL | 57 |
| HEATING COST CURRENT | 650 |
| HEATING COST POTENTIAL | 387 |
| HOT WATER COST CURRENT | 93 |
| HOT WATER COST POTENTIAL | 67 |
| TOTAL FLOOR AREA | 68 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Programmer, no room thermostat |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed during or after 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 2 |
| NUMBER HABITABLE ROOMS | 3 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 50 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | From main system |
| HOT WATER ENERGY EFF | Good |
| HOT WATER ENV EFF | Good |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Good |
| WINDOWS ENV EFF | Good |
| WALLS DESCRIPTION | Solid brick, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Very Poor |
| WALLS ENV EFF | Very Poor |
| SECONDHEAT DESCRIPTION | Room heaters, dual fuel (mineral and wood) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 250 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, mains gas |
| MAINHEAT ENERGY EFF | Good |
| MAINHEAT ENV EFF | Good |
| MAINHEATCONT DESCRIPTION | Programmer, no room thermostat |
| MAINHEATC ENERGY EFF | Very Poor |
| MAINHEATC ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 50% of fixed outlets |
| LIGHTING ENERGY EFF | Good |
| LIGHTING ENV EFF | Good |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.44 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 240, Newington Road |
| LOCAL AUTHORITY LABEL | Thanet |
| CONSTITUENCY LABEL | East Thanet |
| POSTTOWN | RAMSGATE |
| CONSTRUCTION AGE BAND | England and Wales: 1900-1929 |
| LODGEMENT DATETIME | 2019-06-10 15:58:44 |
| TENURE | rented (private) |
| FIXED LIGHTING OUTLETS COUNT | 10 |
| LOW ENERGY FIXED LIGHT COUNT | 5 |
| UPRN | 100061140900 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2019.csv |
| COUNTRY | England |
| REGION | E12000008 |
| Address display | — |
| Nation | ew |