Energy Performance Certificate

59, Alderton Road, Orsett, RM16 3DZ

EPC Report

Energy rating

Current: 65 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 59 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 74 Potential: 74
Field Value
LMK KEY 0867-2860-7781-9221-5581
ADDRESS1 59, Alderton Road
ADDRESS2 Orsett
ADDRESS3
POSTCODE RM16 3DZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2019-08-20
LOCAL AUTHORITY E06000034
CONSTITUENCY E14001480
COUNTY
LODGEMENT DATE 2019-08-21
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 238
ENERGY CONSUMPTION POTENTIAL 131
CO2 EMISSIONS CURRENT 3.3
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 62
LIGHTING COST POTENTIAL 62
HEATING COST CURRENT 570
HEATING COST POTENTIAL 518
HOT WATER COST CURRENT 103
HOT WATER COST POTENTIAL 70
TOTAL FLOOR AREA 80
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 97
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 97% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 1.5
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 59, Alderton Road, Orsett
LOCAL AUTHORITY LABEL Thurrock
CONSTITUENCY LABEL South Basildon and East Thurrock
POSTTOWN GRAYS
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2019-08-21 12:00:06
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 29
UPRN 100090717385
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000006
Address display
Nation ew