Energy Performance Certificate

103, Falcon Crescent, Costessey, NR8 5GX

EPC Report

Energy rating

Current: 82 B | Potential: 91 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 B Current: 82 B 91 B Potential: 91 B

Environmental impact (CO₂)

Current: 82 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 90 Potential: 90
Field Value
LMK KEY 0859-3818-7852-9893-7331
ADDRESS1 103, Falcon Crescent
ADDRESS2 Costessey
ADDRESS3
POSTCODE NR8 5GX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 82
POTENTIAL ENERGY EFFICIENCY 91
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-05-18
LOCAL AUTHORITY E07000149
CONSTITUENCY E14001489
COUNTY
LODGEMENT DATE 2017-05-18
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 101
ENERGY CONSUMPTION POTENTIAL 46
CO2 EMISSIONS CURRENT 2.0
CO2 EMISS CURR PER FLOOR AREA 18
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 326
HEATING COST POTENTIAL 358
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 58
TOTAL FLOOR AREA 112
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.15 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.25 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.17 W/m²K
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.325
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 103, Falcon Crescent, Costessey
LOCAL AUTHORITY LABEL South Norfolk
CONSTITUENCY LABEL South Norfolk
POSTTOWN NORWICH
CONSTRUCTION AGE BAND 2017
LODGEMENT DATETIME 2017-05-18 09:36:41
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 2630187231
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew