Energy Performance Certificate

44, Jutland Crescent, SP10 4NB

EPC Report

Energy rating

Current: 62 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 62 D Current: 62 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 59 | Potential: 82
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 82 Potential: 82
Field Value
LMK KEY 0858-2877-7251-9808-8331
ADDRESS1 44, Jutland Crescent
ADDRESS2
ADDRESS3
POSTCODE SP10 4NB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 62
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-05-03
LOCAL AUTHORITY E07000093
CONSTITUENCY E14001403
COUNTY
LODGEMENT DATE 2018-05-03
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 82
ENERGY CONSUMPTION CURRENT 263
ENERGY CONSUMPTION POTENTIAL 103
CO2 EMISSIONS CURRENT 3.5
CO2 EMISS CURR PER FLOOR AREA 46
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 606
HEATING COST POTENTIAL 479
HOT WATER COST CURRENT 159
HOT WATER COST POTENTIAL 69
TOTAL FLOOR AREA 76
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 91
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 91% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.47
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 44, Jutland Crescent
LOCAL AUTHORITY LABEL Test Valley
CONSTITUENCY LABEL North West Hampshire
POSTTOWN ANDOVER
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2018-05-03 15:37:50
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 200000699689
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew