Energy Performance Certificate

106, Westmorland Avenue, LU3 2PT

EPC Report

Energy rating

Current: 1 G | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 1 G Current: 1 G 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 15 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 15 Current: 15 83 Potential: 83
Field Value
LMK KEY 0852-2804-7876-9403-9165
ADDRESS1 106, Westmorland Avenue
ADDRESS2
ADDRESS3
POSTCODE LU3 2PT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING G
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 1
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2017-03-04
LOCAL AUTHORITY E06000032
CONSTITUENCY E14001345
COUNTY
LODGEMENT DATE 2017-03-04
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 15
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 715
ENERGY CONSUMPTION POTENTIAL 91
CO2 EMISSIONS CURRENT 13
CO2 EMISS CURR PER FLOOR AREA 123
CO2 EMISSIONS POTENTIAL 1.7
LIGHTING COST CURRENT 136
LIGHTING COST POTENTIAL 72
HEATING COST CURRENT 3621
HEATING COST POTENTIAL 493
HOT WATER COST CURRENT 84
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 103
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 20
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 8
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Gas instantaneous at point of use
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 8% of fixed outlets
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 106, Westmorland Avenue
LOCAL AUTHORITY LABEL Luton
CONSTITUENCY LABEL Luton North
POSTTOWN LUTON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2017-03-04 16:36:42
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 1
UPRN 100080183799
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000006
Address display
Nation ew