Energy Performance Certificate

16, Brook Road, CR7 7RB

EPC Report

Energy rating

Current: 59 D | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 D Current: 59 D 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 52 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 52 Current: 52 68 Potential: 68
Field Value
LMK KEY 0848-2892-6652-9491-3465
ADDRESS1 16, Brook Road
ADDRESS2
ADDRESS3
POSTCODE CR7 7RB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 59
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2019-05-12
LOCAL AUTHORITY E09000008
CONSTITUENCY E14001188
COUNTY
LODGEMENT DATE 2019-05-12
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 52
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 288
ENERGY CONSUMPTION POTENTIAL 187
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 51
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 90
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 662
HEATING COST POTENTIAL 429
HOT WATER COST CURRENT 98
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 77
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR no corridor
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.71
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Brook Road
LOCAL AUTHORITY LABEL Croydon
CONSTITUENCY LABEL Croydon West
POSTTOWN THORNTON HEATH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2019-05-12 19:20:34
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 100020691220
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000007
Address display
Nation ew