Energy Performance Certificate

35, Holbein Close, LE11 1PS

EPC Report

Energy rating

Current: 53 E | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 53 E Current: 53 E 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 49 | Potential: 88
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 Current: 49 88 Potential: 88
Field Value
LMK KEY 0847-2883-6617-9395-8905
ADDRESS1 35, Holbein Close
ADDRESS2
ADDRESS3
POSTCODE LE11 1PS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 53
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2015-09-17
LOCAL AUTHORITY E07000130
CONSTITUENCY E14001342
COUNTY
LODGEMENT DATE 2015-09-18
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 49
ENVIRONMENT IMPACT POTENTIAL 88
ENERGY CONSUMPTION CURRENT 482
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 3.1
CO2 EMISS CURR PER FLOOR AREA 85
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 30
LIGHTING COST POTENTIAL 30
HEATING COST CURRENT 624
HEATING COST POTENTIAL 361
HOT WATER COST CURRENT 79
HOT WATER COST POTENTIAL 51
TOTAL FLOOR AREA 36
ENERGY TARIFF dual
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.44
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35, Holbein Close
LOCAL AUTHORITY LABEL Charnwood
CONSTITUENCY LABEL Loughborough
POSTTOWN LOUGHBOROUGH
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2015-09-18 03:17:47
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 4
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 100030446970
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew