Energy Performance Certificate

9, Tarragon Drive, ST3 7YE

EPC Report

Energy rating

Current: 71 C | Potential: 81 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 71 C Current: 71 C 81 B Potential: 81 B

Environmental impact (CO₂)

Current: 66 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 Current: 66 77 Potential: 77
Field Value
LMK KEY 0847-2826-6338-9126-1361
ADDRESS1 9, Tarragon Drive
ADDRESS2
ADDRESS3
POSTCODE ST3 7YE
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 71
POTENTIAL ENERGY EFFICIENCY 81
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2016-07-26
LOCAL AUTHORITY E06000021
CONSTITUENCY E14001522
COUNTY
LODGEMENT DATE 2016-07-26
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 66
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 209
ENERGY CONSUMPTION POTENTIAL 142
CO2 EMISSIONS CURRENT 4.2
CO2 EMISS CURR PER FLOOR AREA 37
CO2 EMISSIONS POTENTIAL 2.9
LIGHTING COST CURRENT 77
LIGHTING COST POTENTIAL 77
HEATING COST CURRENT 775
HEATING COST POTENTIAL 734
HOT WATER COST CURRENT 115
HOT WATER COST POTENTIAL 82
TOTAL FLOOR AREA 114
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 92
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 92% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.32
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 9, Tarragon Drive
LOCAL AUTHORITY LABEL Stoke-on-Trent
CONSTITUENCY LABEL Stoke-on-Trent South
POSTTOWN STOKE-ON-TRENT
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2016-07-26 14:01:52
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 3455094189
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000005
Address display
Nation ew