Energy Performance Certificate

B7a, Oaktree Caravan Site, Allington Lane, SO30 3HR

EPC Report

Energy rating

Current: 38 F | Potential: 60 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 60 D Potential: 60 D

Environmental impact (CO₂)

Current: 33 | Potential: 52
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 52 Potential: 52
Field Value
LMK KEY 0846-2876-7617-9906-3911
ADDRESS1 B7a
ADDRESS2 Oaktree Caravan Site
ADDRESS3 Allington Lane
POSTCODE SO30 3HR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 60
PROPERTY TYPE Park home
BUILT FORM Detached
INSPECTION DATE 2016-09-06
LOCAL AUTHORITY E07000086
CONSTITUENCY E14001220
COUNTY
LODGEMENT DATE 2016-10-21
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 52
ENERGY CONSUMPTION CURRENT 531
ENERGY CONSUMPTION POTENTIAL 341
CO2 EMISSIONS CURRENT 3.8
CO2 EMISS CURR PER FLOOR AREA 138
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 35
LIGHTING COST POTENTIAL 22
HEATING COST CURRENT 434
HEATING COST POTENTIAL 229
HOT WATER COST CURRENT 140
HOT WATER COST POTENTIAL 141
TOTAL FLOOR AREA 27
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE not defined
GLAZED AREA Much More Than Typical
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 40
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Park home wall, as built
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 40% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.1
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS B7a, Oaktree Caravan Site, Allington Lane
LOCAL AUTHORITY LABEL Eastleigh
CONSTITUENCY LABEL Eastleigh
POSTTOWN SOUTHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1976-1982
LODGEMENT DATETIME 2016-10-21 16:04:59
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 5
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10009588462
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000008
Address display
Nation ew