Energy Performance Certificate

6, Martock Close, HA3 8PU

EPC Report

Energy rating

Current: 67 D | Potential: 89 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 89 B Potential: 89 B

Environmental impact (CO₂)

Current: 64 | Potential: 89
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 89 Potential: 89
Field Value
LMK KEY 0845-2867-7587-9696-5381
ADDRESS1 6, Martock Close
ADDRESS2
ADDRESS3
POSTCODE HA3 8PU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 89
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2016-08-13
LOCAL AUTHORITY E09000015
CONSTITUENCY E14001270
COUNTY
LODGEMENT DATE 2016-08-14
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 89
ENERGY CONSUMPTION CURRENT 238
ENERGY CONSUMPTION POTENTIAL 58
CO2 EMISSIONS CURRENT 2.8
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 0.7
LIGHTING COST CURRENT 67
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 427
HEATING COST POTENTIAL 328
HOT WATER COST CURRENT 181
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 66
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 55
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 55% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Martock Close
LOCAL AUTHORITY LABEL Harrow
CONSTITUENCY LABEL Harrow East
POSTTOWN HARROW
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2016-08-14 20:50:13
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100021277362
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000007
Address display
Nation ew