Energy Performance Certificate

23, Eaton Crescent, SA1 4QJ

EPC Report

Energy rating

Current: 58 D | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 48 | Potential: 73
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 48 Current: 48 73 Potential: 73
Field Value
LMK KEY 0844-2831-7170-9506-6341
ADDRESS1 23, Eaton Crescent
ADDRESS2
ADDRESS3
POSTCODE SA1 4QJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-03-09
LOCAL AUTHORITY W06000011
CONSTITUENCY W07000108
COUNTY
LODGEMENT DATE 2016-03-24
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 48
ENVIRONMENT IMPACT POTENTIAL 73
ENERGY CONSUMPTION CURRENT 235
ENERGY CONSUMPTION POTENTIAL 111
CO2 EMISSIONS CURRENT 9.1
CO2 EMISS CURR PER FLOOR AREA 41
CO2 EMISSIONS POTENTIAL 4.3
LIGHTING COST CURRENT 143
LIGHTING COST POTENTIAL 98
HEATING COST CURRENT 1689
HEATING COST POTENTIAL 982
HOT WATER COST CURRENT 134
HOT WATER COST POTENTIAL 119
TOTAL FLOOR AREA 219
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 3
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 83
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 55
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 55% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.7
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 23, Eaton Crescent
LOCAL AUTHORITY LABEL Swansea
CONSTITUENCY LABEL Swansea West
POSTTOWN SWANSEA
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-03-24 09:26:08
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 22
LOW ENERGY FIXED LIGHT COUNT 12
UPRN 100100351826
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew