Energy Performance Certificate

19a South Street, PE19 2BW

EPC Report

Energy rating

Current: 31 F | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 18 | Potential: 66
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 18 Current: 18 66 Potential: 66
Field Value
LMK KEY 0843-2871-7314-9396-1201
ADDRESS1 19a South Street
ADDRESS2
ADDRESS3
POSTCODE PE19 2BW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2016-09-19
LOCAL AUTHORITY E07000011
CONSTITUENCY E14001512
COUNTY
LODGEMENT DATE 2016-09-20
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 18
ENVIRONMENT IMPACT POTENTIAL 66
ENERGY CONSUMPTION CURRENT 664
ENERGY CONSUMPTION POTENTIAL 190
CO2 EMISSIONS CURRENT 12
CO2 EMISS CURR PER FLOOR AREA 112
CO2 EMISSIONS POTENTIAL 3.3
LIGHTING COST CURRENT 89
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 1780
HEATING COST POTENTIAL 582
HOT WATER COST CURRENT 241
HOT WATER COST POTENTIAL 109
TOTAL FLOOR AREA 104
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 55
GLAZED TYPE secondary glazing
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION Electric instantaneous at point of use
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial secondary glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.14
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 19a South Street
LOCAL AUTHORITY LABEL Huntingdonshire
CONSTITUENCY LABEL St Neots and Mid Cambridgeshire
POSTTOWN ST. NEOTS
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2016-09-20 17:53:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 10000162534
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000006
Address display