Energy Performance Certificate

40, Short Stocks, NN10 0EB

EPC Report

Energy rating

Current: 43 E | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 42 | Potential: 69
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 42 Current: 42 69 Potential: 69
Field Value
LMK KEY 0839-2841-7972-9305-6541
ADDRESS1 40, Short Stocks
ADDRESS2
ADDRESS3
POSTCODE NN10 0EB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2015-03-09
LOCAL AUTHORITY E06000061
CONSTITUENCY E14001571
COUNTY
LODGEMENT DATE 2015-03-19
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 42
ENVIRONMENT IMPACT POTENTIAL 69
ENERGY CONSUMPTION CURRENT 404
ENERGY CONSUMPTION POTENTIAL 194
CO2 EMISSIONS CURRENT 5.8
CO2 EMISS CURR PER FLOOR AREA 68
CO2 EMISSIONS POTENTIAL 2.8
LIGHTING COST CURRENT 75
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 1054
HEATING COST POTENTIAL 453
HOT WATER COST CURRENT 270
HOT WATER COST POTENTIAL 91
TOTAL FLOOR AREA 85
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 64
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 64% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 40, Short Stocks
LOCAL AUTHORITY LABEL North Northamptonshire
CONSTITUENCY LABEL Wellingborough and Rushden
POSTTOWN RUSHDEN
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-03-19 20:10:12
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100031037757
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000004
Address display
Nation ew