Energy Performance Certificate

6 Lowbridge Court, Garston, L19 2JP

EPC Report

Energy rating

Current: 46 E | Potential: 66 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 E Current: 46 E 66 D Potential: 66 D

Environmental impact (CO₂)

Current: 45 | Potential: 44
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 44 Potential: 44
Field Value
LMK KEY 0839-0828-3000-0050-8292
ADDRESS1 6 Lowbridge Court
ADDRESS2 Garston
ADDRESS3
POSTCODE L19 2JP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 46
POTENTIAL ENERGY EFFICIENCY 66
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2021-08-10
LOCAL AUTHORITY E08000012
CONSTITUENCY E14001337
COUNTY
LODGEMENT DATE 2021-08-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 44
ENERGY CONSUMPTION CURRENT 398
ENERGY CONSUMPTION POTENTIAL 401
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 67
CO2 EMISSIONS POTENTIAL 4.6
LIGHTING COST CURRENT 80
LIGHTING COST POTENTIAL 93
HEATING COST CURRENT 1031
HEATING COST POTENTIAL 661
HOT WATER COST CURRENT 237
HOT WATER COST POTENTIAL 187
TOTAL FLOOR AREA 68
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 3
NUMBER HEATED ROOMS 3
LOW ENERGY LIGHTING 86
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (another dwelling below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, partial insulation (assumed)
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 86% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR unheated corridor
UNHEATED CORRIDOR LENGTH 10.43
FLOOR HEIGHT 2.26
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6 Lowbridge Court, Garston
LOCAL AUTHORITY LABEL Liverpool
CONSTITUENCY LABEL Liverpool Garston
POSTTOWN LIVERPOOL
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2021-08-10 17:13:33
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 38249882
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2021.csv
COUNTRY England
REGION E12000002
Address display
Nation ew