Energy Performance Certificate
24, Thorpe Avenue, Moulton Chapel, PE12 0XN
Energy rating
Current: 59 D | Potential: 83 B
Environmental impact (CO₂)
Current: 27
| Potential: 48
| Field | Value |
|---|---|
| LMK KEY | 0838-2853-7141-9205-4055 |
| ADDRESS1 | 24, Thorpe Avenue |
| ADDRESS2 | Moulton Chapel |
| ADDRESS3 | — |
| POSTCODE | PE12 0XN |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 59 |
| POTENTIAL ENERGY EFFICIENCY | 83 |
| PROPERTY TYPE | House |
| BUILT FORM | Semi-Detached |
| INSPECTION DATE | 2015-04-07 |
| LOCAL AUTHORITY | E07000140 |
| CONSTITUENCY | E14001487 |
| COUNTY | — |
| LODGEMENT DATE | 2015-04-14 |
| TRANSACTION TYPE | Rental |
| ENVIRONMENT IMPACT CURRENT | 27 |
| ENVIRONMENT IMPACT POTENTIAL | 48 |
| ENERGY CONSUMPTION CURRENT | 285 |
| ENERGY CONSUMPTION POTENTIAL | 119 |
| CO2 EMISSIONS CURRENT | 7.6 |
| CO2 EMISS CURR PER FLOOR AREA | 100 |
| CO2 EMISSIONS POTENTIAL | 4.4 |
| LIGHTING COST CURRENT | 77 |
| LIGHTING COST POTENTIAL | 49 |
| HEATING COST CURRENT | 557 |
| HEATING COST POTENTIAL | 450 |
| HOT WATER COST CURRENT | 258 |
| HOT WATER COST POTENTIAL | 103 |
| TOTAL FLOOR AREA | 76 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | N |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | No time or thermostatic control of room temperature |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | double glazing installed before 2002 |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 5 |
| NUMBER HEATED ROOMS | 5 |
| LOW ENERGY LIGHTING | 44 |
| NUMBER OPEN FIREPLACES | 1 |
| HOTWATER DESCRIPTION | From main system, no cylinder thermostat |
| HOT WATER ENERGY EFF | Poor |
| HOT WATER ENV EFF | Very Poor |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, filled cavity |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | None |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 200 mm loft insulation |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Boiler and radiators, coal |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | No time or thermostatic control of room temperature |
| MAINHEATC ENERGY EFF | Very Poor |
| MAINHEATC ENV EFF | Very Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 44% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| MAIN FUEL | house coal (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.45 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 24, Thorpe Avenue, Moulton Chapel |
| LOCAL AUTHORITY LABEL | South Holland |
| CONSTITUENCY LABEL | South Holland and The Deepings |
| POSTTOWN | SPALDING |
| CONSTRUCTION AGE BAND | England and Wales: 1930-1949 |
| LODGEMENT DATETIME | 2015-04-14 10:39:31 |
| TENURE | rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 9 |
| LOW ENERGY FIXED LIGHT COUNT | 4 |
| UPRN | 100030897205 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2015.csv |
| COUNTRY | England |
| REGION | E12000004 |
| Address display | — |
| Nation | ew |