Energy Performance Certificate

32b Summer Lake, Spine Road East, South Cerney, GL7 5LW

EPC Report

Energy rating

Current: 69 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 72 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 72 Current: 72 81 Potential: 81
Field Value
LMK KEY 0837-5022-0200-0317-4296
ADDRESS1 32b Summer Lake
ADDRESS2 Spine Road East
ADDRESS3 South Cerney
POSTCODE GL7 5LW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-02-13
LOCAL AUTHORITY E07000079
CONSTITUENCY E14001482
COUNTY
LODGEMENT DATE 2023-02-17
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 72
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 152
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 4.1
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 205
LIGHTING COST POTENTIAL 205
HEATING COST CURRENT 2159
HEATING COST POTENTIAL 2052
HOT WATER COST CURRENT 528
HOT WATER COST POTENTIAL 339
TOTAL FLOOR AREA 159
ENERGY TARIFF Single
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric, Air source heat pump, radiators, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.34
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 32b Summer Lake, Spine Road East, South Cerney
LOCAL AUTHORITY LABEL Cotswold
CONSTITUENCY LABEL South Cotswolds
POSTTOWN CIRENCESTER
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2023-02-17 06:57:49
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 15
LOW ENERGY FIXED LIGHT COUNT 15
UPRN 10024444706
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000009
Address display
Nation ew