Energy Performance Certificate

35, Keble Road, Gorleston, NR31 7NA

EPC Report

Energy rating

Current: 33 F | Potential: 87 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 F Current: 33 F 87 B Potential: 87 B

Environmental impact (CO₂)

Current: 45 | Potential: 85
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 45 Current: 45 85 Potential: 85
Field Value
LMK KEY 0834-2820-7895-9275-8095
ADDRESS1 35, Keble Road
ADDRESS2 Gorleston
ADDRESS3
POSTCODE NR31 7NA
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 33
POTENTIAL ENERGY EFFICIENCY 87
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-01-30
LOCAL AUTHORITY E07000145
CONSTITUENCY E14001256
COUNTY
LODGEMENT DATE 2015-01-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 45
ENVIRONMENT IMPACT POTENTIAL 85
ENERGY CONSUMPTION CURRENT 371
ENERGY CONSUMPTION POTENTIAL 81
CO2 EMISSIONS CURRENT 5.7
CO2 EMISS CURR PER FLOOR AREA 63
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 114
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 1273
HEATING COST POTENTIAL 462
HOT WATER COST CURRENT 351
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 91
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS None
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 0
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION No system present: electric heaters assumed
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION None
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL To be used only when there is no heating/hot-water system or data is from a community network
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.42
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 35, Keble Road, Gorleston
LOCAL AUTHORITY LABEL Great Yarmouth
CONSTITUENCY LABEL Great Yarmouth
POSTTOWN GREAT YARMOUTH
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2015-01-30 12:21:05
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100090844702
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000006
Address display
Nation ew