Energy Performance Certificate

3 The Barn, Warrens Yard, Trefrew Road, PL32 9TP

EPC Report

Energy rating

Current: 70 C | Potential: 70 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 70 C Current: 70 C 70 C Potential: 70 C

Environmental impact (CO₂)

Current: 59 | Potential: 59
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 59 Potential: 59
Field Value
LMK KEY 0833-3862-7965-9795-5625
ADDRESS1 3 The Barn, Warrens Yard
ADDRESS2 Trefrew Road
ADDRESS3
POSTCODE PL32 9TP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 70
POTENTIAL ENERGY EFFICIENCY 70
PROPERTY TYPE Flat
BUILT FORM Semi-Detached
INSPECTION DATE 2015-06-12
LOCAL AUTHORITY E06000052
CONSTITUENCY E14001385
COUNTY
LODGEMENT DATE 2015-06-12
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 59
ENERGY CONSUMPTION CURRENT 361
ENERGY CONSUMPTION POTENTIAL 361
CO2 EMISSIONS CURRENT 3.4
CO2 EMISS CURR PER FLOOR AREA 61
CO2 EMISSIONS POTENTIAL 3.4
LIGHTING COST CURRENT 56
LIGHTING COST POTENTIAL 56
HEATING COST CURRENT 391
HEATING COST POTENTIAL 391
HOT WATER COST CURRENT 179
HOT WATER COST POTENTIAL 179
TOTAL FLOOR AREA 55
ENERGY TARIFF off-peak 7 hour
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 75
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.28 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 75% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 3 The Barn, Warrens Yard, Trefrew Road
LOCAL AUTHORITY LABEL Cornwall
CONSTITUENCY LABEL North Cornwall
POSTTOWN CAMELFORD
CONSTRUCTION AGE BAND 2014
LODGEMENT DATETIME 2015-06-12 13:39:04
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 10093251253
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew