Energy Performance Certificate

3, The Square, Main Street, DE15 0SQ

EPC Report

Energy rating

Current: 37 F | Potential: 93 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 F Current: 37 F 93 A Potential: 93 A

Environmental impact (CO₂)

Current: 22 | Potential: 79
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 22 Current: 22 79 Potential: 79
Field Value
LMK KEY 0829-2827-7140-9524-8135
ADDRESS1 3, The Square
ADDRESS2 Main Street
ADDRESS3
POSTCODE DE15 0SQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 37
POTENTIAL ENERGY EFFICIENCY 93
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-04-23
LOCAL AUTHORITY E07000039
CONSTITUENCY E14001483
COUNTY
LODGEMENT DATE 2014-04-23
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 22
ENVIRONMENT IMPACT POTENTIAL 79
ENERGY CONSUMPTION CURRENT 753
ENERGY CONSUMPTION POTENTIAL 158
CO2 EMISSIONS CURRENT 7.1
CO2 EMISS CURR PER FLOOR AREA 133
CO2 EMISSIONS POTENTIAL 1.5
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 884
HEATING COST POTENTIAL 272
HOT WATER COST CURRENT 224
HOT WATER COST POTENTIAL 74
TOTAL FLOOR AREA 53
ENERGY TARIFF dual
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 33
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 33% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, The Square, Main Street
LOCAL AUTHORITY LABEL South Derbyshire
CONSTITUENCY LABEL South Derbyshire
POSTTOWN BURTON-ON-TRENT
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2014-04-23 22:35:41
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 3
UPRN 100030232179
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000004
Address display
Nation ew