Energy Performance Certificate

7 Glossop Close, WA1 2GS

EPC Report

Energy rating

Current: 78 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 78 C Current: 78 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 82 | Potential: 83
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 82 Current: 82 83 Potential: 83
Field Value
LMK KEY 0828-4095-7348-0412-6984
ADDRESS1 7 Glossop Close
ADDRESS2
ADDRESS3
POSTCODE WA1 2GS
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 78
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2012-08-02
LOCAL AUTHORITY E06000007
CONSTITUENCY E14001564
COUNTY
LODGEMENT DATE 2012-09-14
TRANSACTION TYPE new dwelling
ENVIRONMENT IMPACT CURRENT 82
ENVIRONMENT IMPACT POTENTIAL 83
ENERGY CONSUMPTION CURRENT 128
ENERGY CONSUMPTION POTENTIAL 120
CO2 EMISSIONS CURRENT 1.4
CO2 EMISS CURR PER FLOOR AREA 24
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 58
LIGHTING COST POTENTIAL 33
HEATING COST CURRENT 240
HEATING COST POTENTIAL 243
HOT WATER COST CURRENT 79
HOT WATER COST POTENTIAL 79
TOTAL FLOOR AREA 56
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.21 W/m²K
FLOOR ENERGY EFF Good
FLOOR ENV EFF Good
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Average thermal transmittance 0.29 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.14 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL Gas: mains gas
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 7 Glossop Close
LOCAL AUTHORITY LABEL Warrington
CONSTITUENCY LABEL Warrington North
POSTTOWN WARRINGTON
CONSTRUCTION AGE BAND 2012
LODGEMENT DATETIME 2012-09-14 12:45:43
TENURE
FIXED LIGHTING OUTLETS COUNT 0
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 10090371961
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2012.csv
COUNTRY England
REGION E12000002
Address display