Energy Performance Certificate

Sunnyside, Long Common, Claverley, WV5 7AX

EPC Report

Energy rating

Current: 26 F | Potential: 58 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 F Current: 26 F 58 D Potential: 58 D

Environmental impact (CO₂)

Current: 20 | Potential: 44
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 20 Current: 20 44 Potential: 44
Field Value
LMK KEY 0828-2809-7972-9894-6325
ADDRESS1 Sunnyside
ADDRESS2 Long Common
ADDRESS3 Claverley
POSTCODE WV5 7AX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 26
POTENTIAL ENERGY EFFICIENCY 58
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2014-03-11
LOCAL AUTHORITY E06000051
CONSTITUENCY E14001493
COUNTY
LODGEMENT DATE 2014-03-12
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 20
ENVIRONMENT IMPACT POTENTIAL 44
ENERGY CONSUMPTION CURRENT 398
ENERGY CONSUMPTION POTENTIAL 212
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 99
CO2 EMISSIONS POTENTIAL 8.7
LIGHTING COST CURRENT 103
LIGHTING COST POTENTIAL 75
HEATING COST CURRENT 2983
HEATING COST POTENTIAL 1882
HOT WATER COST CURRENT 316
HOT WATER COST POTENTIAL 207
TOTAL FLOOR AREA 158
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 15
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 61
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 61% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS Sunnyside, Long Common, Claverley
LOCAL AUTHORITY LABEL Shropshire
CONSTITUENCY LABEL South Shropshire
POSTTOWN WOLVERHAMPTON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-03-12 16:42:00
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 200003850939
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000005
Address display
Nation ew