Energy Performance Certificate

22, Hillside, Ancaster, NG32 3PX

EPC Report

Energy rating

Current: 51 E | Potential: 83 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 83 B Potential: 83 B

Environmental impact (CO₂)

Current: 33 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 33 Current: 33 63 Potential: 63
Field Value
LMK KEY 0825-2880-7719-9891-7845
ADDRESS1 22, Hillside
ADDRESS2 Ancaster
ADDRESS3
POSTCODE NG32 3PX
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 83
PROPERTY TYPE Bungalow
BUILT FORM Semi-Detached
INSPECTION DATE 2019-09-10
LOCAL AUTHORITY E07000141
CONSTITUENCY E14001253
COUNTY
LODGEMENT DATE 2019-10-04
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 33
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 551
ENERGY CONSUMPTION POTENTIAL 258
CO2 EMISSIONS CURRENT 6.7
CO2 EMISS CURR PER FLOOR AREA 93
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 133
LIGHTING COST POTENTIAL 67
HEATING COST CURRENT 1053
HEATING COST POTENTIAL 624
HOT WATER COST CURRENT 187
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 72
ENERGY TARIFF dual
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Manual charge control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, off-peak
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, limited insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Roof room(s), insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Electric storage heaters
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Very Poor
MAINHEATCONT DESCRIPTION Manual charge control
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL electricity (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.6
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Hillside, Ancaster
LOCAL AUTHORITY LABEL South Kesteven
CONSTITUENCY LABEL Grantham and Bourne
POSTTOWN GRANTHAM
CONSTRUCTION AGE BAND England and Wales: 1996-2002
LODGEMENT DATETIME 2019-10-04 11:22:50
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100030917615
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2019.csv
COUNTRY England
REGION E12000004
Address display
Nation ew