Energy Performance Certificate

16, Bolwell Close, Twyford, RG10 0LN

EPC Report

Energy rating

Current: 67 D | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 67 D Current: 67 D 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 65 | Potential: 90
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 Current: 65 90 Potential: 90
Field Value
LMK KEY 0822-2842-7547-9825-0301
ADDRESS1 16, Bolwell Close
ADDRESS2 Twyford
ADDRESS3
POSTCODE RG10 0LN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 67
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-04-22
LOCAL AUTHORITY E06000041
CONSTITUENCY E14001593
COUNTY
LODGEMENT DATE 2015-04-22
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 65
ENVIRONMENT IMPACT POTENTIAL 90
ENERGY CONSUMPTION CURRENT 240
ENERGY CONSUMPTION POTENTIAL 45
CO2 EMISSIONS CURRENT 2.6
CO2 EMISS CURR PER FLOOR AREA 42
CO2 EMISSIONS POTENTIAL 0.5
LIGHTING COST CURRENT 70
LIGHTING COST POTENTIAL 41
HEATING COST CURRENT 397
HEATING COST POTENTIAL 291
HOT WATER COST CURRENT 166
HOT WATER COST POTENTIAL 87
TOTAL FLOOR AREA 60
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, no room thermostat
MULTI GLAZE PROPORTION 0
GLAZED TYPE not defined
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 29
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazed
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Timber frame, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Warm air, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, no room thermostat
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION Low energy lighting in 29% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 16, Bolwell Close, Twyford
LOCAL AUTHORITY LABEL Wokingham
CONSTITUENCY LABEL Wokingham
POSTTOWN READING
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2015-04-22 13:36:00
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 7
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 14041131
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000008
Address display
Nation ew