Energy Performance Certificate
23, Boulevard, PR1 4PE
Energy rating
Current: 39 E | Potential: 85 B
Environmental impact (CO₂)
Current: 39
| Potential: 83
| Field | Value |
|---|---|
| LMK KEY | 0818-5089-7232-5768-1990 |
| ADDRESS1 | 23, Boulevard |
| ADDRESS2 | — |
| ADDRESS3 | — |
| POSTCODE | PR1 4PE |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | E |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 39 |
| POTENTIAL ENERGY EFFICIENCY | 85 |
| PROPERTY TYPE | House |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2018-02-09 |
| LOCAL AUTHORITY | E07000123 |
| CONSTITUENCY | E14001433 |
| COUNTY | — |
| LODGEMENT DATE | 2018-02-09 |
| TRANSACTION TYPE | Marketed sale |
| ENVIRONMENT IMPACT CURRENT | 39 |
| ENVIRONMENT IMPACT POTENTIAL | 83 |
| ENERGY CONSUMPTION CURRENT | 400 |
| ENERGY CONSUMPTION POTENTIAL | 96 |
| CO2 EMISSIONS CURRENT | 6.4 |
| CO2 EMISS CURR PER FLOOR AREA | 70 |
| CO2 EMISSIONS POTENTIAL | 1.6 |
| LIGHTING COST CURRENT | 107 |
| LIGHTING COST POTENTIAL | 62 |
| HEATING COST CURRENT | 1040 |
| HEATING COST POTENTIAL | 445 |
| HOT WATER COST CURRENT | 418 |
| HOT WATER COST POTENTIAL | 75 |
| TOTAL FLOOR AREA | 92 |
| ENERGY TARIFF | Single |
| MAINS GAS FLAG | Y |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | No thermostatic control of room temperature |
| MULTI GLAZE PROPORTION | 90 |
| GLAZED TYPE | double glazing, unknown install date |
| GLAZED AREA | Normal |
| EXTENSION COUNT | 2 |
| NUMBER HABITABLE ROOMS | 5 |
| NUMBER HEATED ROOMS | 2 |
| LOW ENERGY LIGHTING | 27 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Electric immersion, standard tariff |
| HOT WATER ENERGY EFF | Very Poor |
| HOT WATER ENV EFF | Poor |
| FLOOR DESCRIPTION | Suspended, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Mostly double glazing |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Cavity wall, as built, no insulation (assumed) |
| WALLS ENERGY EFF | Poor |
| WALLS ENV EFF | Poor |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, 100 mm loft insulation |
| ROOF ENERGY EFF | Average |
| ROOF ENV EFF | Average |
| MAINHEAT DESCRIPTION | Room heaters, mains gas, Room heaters, mains gas |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Average |
| MAINHEATCONT DESCRIPTION | No thermostatic control of room temperature |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 27% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| MAIN FUEL | mains gas (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.64 |
| PHOTO SUPPLY | 0 |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 23, Boulevard |
| LOCAL AUTHORITY LABEL | Preston |
| CONSTITUENCY LABEL | Preston |
| POSTTOWN | PRESTON |
| CONSTRUCTION AGE BAND | England and Wales: 1930-1949 |
| LODGEMENT DATETIME | 2018-02-09 17:41:08 |
| TENURE | unknown |
| FIXED LIGHTING OUTLETS COUNT | 11 |
| LOW ENERGY FIXED LIGHT COUNT | 3 |
| UPRN | 10007601253 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2018.csv |
| COUNTRY | England |
| REGION | E12000002 |
| Address display | — |
| Nation | ew |