Energy Performance Certificate

77 High Street, Maiden Bradley, BA12 7JG

EPC Report

Energy rating

Current: 31 F | Potential: 78 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 31 F Current: 31 F 78 C Potential: 78 C

Environmental impact (CO₂)

Current: 30 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 74 Potential: 74
Field Value
LMK KEY 0818-3016-7205-7432-1204
ADDRESS1 77 High Street
ADDRESS2 Maiden Bradley
ADDRESS3
POSTCODE BA12 7JG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 31
POTENTIAL ENERGY EFFICIENCY 78
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2022-05-09
LOCAL AUTHORITY E06000054
CONSTITUENCY E14001498
COUNTY
LODGEMENT DATE 2022-05-10
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 356
ENERGY CONSUMPTION POTENTIAL 99
CO2 EMISSIONS CURRENT 9.0
CO2 EMISS CURR PER FLOOR AREA 87
CO2 EMISSIONS POTENTIAL 2.7
LIGHTING COST CURRENT 117
LIGHTING COST POTENTIAL 82
HEATING COST CURRENT 1118
HEATING COST POTENTIAL 513
HOT WATER COST CURRENT 240
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 104
ENERGY TARIFF Unknown
MAINS GAS FLAG N
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 57
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Granite or whinstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, oil
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 57% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL oil (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.54
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 77 High Street, Maiden Bradley
LOCAL AUTHORITY LABEL Wiltshire
CONSTITUENCY LABEL South West Wiltshire
POSTTOWN WARMINSTER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2022-05-10 13:40:48
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 14
LOW ENERGY FIXED LIGHT COUNT 8
UPRN 100121062944
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2022.csv
COUNTRY England
REGION E12000009
Address display
Nation ew