Energy Performance Certificate

6, Sutton Fields, Sutton-in-Craven, BD20 8BN

EPC Report

Energy rating

Current: 49 E | Potential: 95 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 49 E Current: 49 E 95 A Potential: 95 A

Environmental impact (CO₂)

Current: 46 | Potential: 98
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 98 Potential: 98
Field Value
LMK KEY 0818-2888-7298-9104-0425
ADDRESS1 6, Sutton Fields
ADDRESS2 Sutton-in-Craven
ADDRESS3
POSTCODE BD20 8BN
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 49
POTENTIAL ENERGY EFFICIENCY 95
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-01-08
LOCAL AUTHORITY E06000065
CONSTITUENCY E14001475
COUNTY
LODGEMENT DATE 2014-01-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 98
ENERGY CONSUMPTION CURRENT 396
ENERGY CONSUMPTION POTENTIAL 8
CO2 EMISSIONS CURRENT 4.0
CO2 EMISS CURR PER FLOOR AREA 77
CO2 EMISSIONS POTENTIAL 0.1
LIGHTING COST CURRENT 60
LIGHTING COST POTENTIAL 34
HEATING COST CURRENT 782
HEATING COST POTENTIAL 314
HOT WATER COST CURRENT 75
HOT WATER COST POTENTIAL 55
TOTAL FLOOR AREA 53
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 2
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 25
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 25% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.64
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Sutton Fields, Sutton-in-Craven
LOCAL AUTHORITY LABEL North Yorkshire
CONSTITUENCY LABEL Skipton and Ripon
POSTTOWN KEIGHLEY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2014-01-08 15:00:46
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 10007562472
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000003
Address display
Nation ew