Energy Performance Certificate

17, Manley Road, LL13 8HD

EPC Report

Energy rating

Current: 26 F | Potential: 69 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 26 F Current: 26 F 69 C Potential: 69 C

Environmental impact (CO₂)

Current: 23 | Potential: 62
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 23 Current: 23 62 Potential: 62
Field Value
LMK KEY 0812-2825-7388-9307-8625
ADDRESS1 17, Manley Road
ADDRESS2
ADDRESS3
POSTCODE LL13 8HD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 26
POTENTIAL ENERGY EFFICIENCY 69
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-08-05
LOCAL AUTHORITY W06000006
CONSTITUENCY W07000111
COUNTY
LODGEMENT DATE 2013-08-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 23
ENVIRONMENT IMPACT POTENTIAL 62
ENERGY CONSUMPTION CURRENT 443
ENERGY CONSUMPTION POTENTIAL 172
CO2 EMISSIONS CURRENT 18
CO2 EMISS CURR PER FLOOR AREA 86
CO2 EMISSIONS POTENTIAL 6.9
LIGHTING COST CURRENT 169
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 3149
HEATING COST POTENTIAL 1388
HOT WATER COST CURRENT 83
HOT WATER COST POTENTIAL 99
TOTAL FLOOR AREA 205
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Appliance thermostats
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 2
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Room heaters, mains gas
MAINHEAT ENERGY EFF Average
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Appliance thermostats
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 17, Manley Road
LOCAL AUTHORITY LABEL Wrexham
CONSTITUENCY LABEL Wrexham
POSTTOWN WREXHAM
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2013-08-08 13:34:28
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100100860373
UPRN SOURCE Address Matched
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew