Energy Performance Certificate

6, Mallard View, Oxenhope, BD22 9JZ

EPC Report

Energy rating

Current: 69 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 C Current: 69 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 69 | Potential: 92
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 69 Current: 69 92 Potential: 92
Field Value
LMK KEY 0812-2810-7635-9527-3631
ADDRESS1 6, Mallard View
ADDRESS2 Oxenhope
ADDRESS3
POSTCODE BD22 9JZ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 69
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2013-07-20
LOCAL AUTHORITY E08000032
CONSTITUENCY E14001308
COUNTY
LODGEMENT DATE 2013-07-20
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 69
ENVIRONMENT IMPACT POTENTIAL 92
ENERGY CONSUMPTION CURRENT 208
ENERGY CONSUMPTION POTENTIAL 47
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 40
CO2 EMISSIONS POTENTIAL 0.6
LIGHTING COST CURRENT 52
LIGHTING COST POTENTIAL 38
HEATING COST CURRENT 438
HEATING COST POTENTIAL 337
HOT WATER COST CURRENT 99
HOT WATER COST POTENTIAL 56
TOTAL FLOOR AREA 61
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 62
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 100 mm loft insulation
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 62% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.37
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6, Mallard View, Oxenhope
LOCAL AUTHORITY LABEL Bradford
CONSTITUENCY LABEL Keighley and Ilkley
POSTTOWN KEIGHLEY
CONSTRUCTION AGE BAND England and Wales: 1991-1995
LODGEMENT DATETIME 2013-07-20 13:07:25
TENURE Rented (private)
FIXED LIGHTING OUTLETS COUNT 8
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 200001103929
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000003
Address display
Nation ew