Energy Performance Certificate

57, Kemble Road, SE23 2DH

EPC Report

Energy rating

Current: 43 E | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 36 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 36 Current: 36 78 Potential: 78
Field Value
LMK KEY 0810-2894-7352-9594-4185
ADDRESS1 57, Kemble Road
ADDRESS2
ADDRESS3
POSTCODE SE23 2DH
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-05-14
LOCAL AUTHORITY E09000023
CONSTITUENCY E14001333
COUNTY
LODGEMENT DATE 2014-05-14
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 36
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 345
ENERGY CONSUMPTION POTENTIAL 92
CO2 EMISSIONS CURRENT 7.4
CO2 EMISS CURR PER FLOOR AREA 73
CO2 EMISSIONS POTENTIAL 2.2
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 64
HEATING COST CURRENT 1163
HEATING COST POTENTIAL 555
HOT WATER COST CURRENT 260
HOT WATER COST POTENTIAL 86
TOTAL FLOOR AREA 102
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 0
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 90
NUMBER OPEN FIREPLACES 4
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Single glazeddouble glazing
WINDOWS ENERGY EFF Very Poor
WINDOWS ENV EFF Very Poor
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, smokeless fuel
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 90% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.8
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 57, Kemble Road
LOCAL AUTHORITY LABEL Lewisham
CONSTITUENCY LABEL Lewisham West and East Dulwich
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-05-14 19:27:55
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100021972915
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000007
Address display
Nation ew