Energy Performance Certificate
50, Oakside, Denham, UB9 4BX
Energy rating
Current: 62 D | Potential: 83 B
Environmental impact (CO₂)
Current: 42
| Potential: 62
| Field | Value |
|---|---|
| LMK KEY | 0809-2885-7872-9597-6035 |
| ADDRESS1 | 50, Oakside |
| ADDRESS2 | Denham |
| ADDRESS3 | — |
| POSTCODE | UB9 4BX |
| BUILDING REFERENCE NUMBER | — |
| CURRENT ENERGY RATING | D |
| POTENTIAL ENERGY RATING | B |
| CURRENT ENERGY EFFICIENCY | 62 |
| POTENTIAL ENERGY EFFICIENCY | 83 |
| PROPERTY TYPE | House |
| BUILT FORM | Mid-Terrace |
| INSPECTION DATE | 2013-03-15 |
| LOCAL AUTHORITY | E06000060 |
| CONSTITUENCY | E14001082 |
| COUNTY | — |
| LODGEMENT DATE | 2013-06-14 |
| TRANSACTION TYPE | Rental |
| ENVIRONMENT IMPACT CURRENT | 42 |
| ENVIRONMENT IMPACT POTENTIAL | 62 |
| ENERGY CONSUMPTION CURRENT | 401 |
| ENERGY CONSUMPTION POTENTIAL | 241 |
| CO2 EMISSIONS CURRENT | 4.8 |
| CO2 EMISS CURR PER FLOOR AREA | 71 |
| CO2 EMISSIONS POTENTIAL | 2.9 |
| LIGHTING COST CURRENT | 77 |
| LIGHTING COST POTENTIAL | 44 |
| HEATING COST CURRENT | 505 |
| HEATING COST POTENTIAL | 424 |
| HOT WATER COST CURRENT | 132 |
| HOT WATER COST POTENTIAL | 81 |
| TOTAL FLOOR AREA | 68 |
| ENERGY TARIFF | dual |
| MAINS GAS FLAG | — |
| FLOOR LEVEL | — |
| FLAT TOP STOREY | N |
| FLAT STOREY COUNT | 2 |
| MAIN HEATING CONTROLS | Manual charge control |
| MULTI GLAZE PROPORTION | 100 |
| GLAZED TYPE | — |
| GLAZED AREA | — |
| EXTENSION COUNT | 0 |
| NUMBER HABITABLE ROOMS | 3 |
| NUMBER HEATED ROOMS | 3 |
| LOW ENERGY LIGHTING | 25 |
| NUMBER OPEN FIREPLACES | 0 |
| HOTWATER DESCRIPTION | Electric immersion, off-peak |
| HOT WATER ENERGY EFF | Average |
| HOT WATER ENV EFF | Very Poor |
| FLOOR DESCRIPTION | Solid, no insulation (assumed) |
| FLOOR ENERGY EFF | N/A |
| FLOOR ENV EFF | N/A |
| WINDOWS DESCRIPTION | Fully double glazed |
| WINDOWS ENERGY EFF | Average |
| WINDOWS ENV EFF | Average |
| WALLS DESCRIPTION | Timber frame, as built, insulated (assumed) |
| WALLS ENERGY EFF | Good |
| WALLS ENV EFF | Good |
| SECONDHEAT DESCRIPTION | Portable electric heaters (assumed) |
| SHEATING ENERGY EFF | N/A |
| SHEATING ENV EFF | N/A |
| ROOF DESCRIPTION | Pitched, insulated (assumed) |
| ROOF ENERGY EFF | Good |
| ROOF ENV EFF | Good |
| MAINHEAT DESCRIPTION | Electric storage heaters |
| MAINHEAT ENERGY EFF | Average |
| MAINHEAT ENV EFF | Very Poor |
| MAINHEATCONT DESCRIPTION | Manual charge control |
| MAINHEATC ENERGY EFF | Poor |
| MAINHEATC ENV EFF | Poor |
| LIGHTING DESCRIPTION | Low energy lighting in 25% of fixed outlets |
| LIGHTING ENERGY EFF | Average |
| LIGHTING ENV EFF | Average |
| MAIN FUEL | electricity (not community) |
| WIND TURBINE COUNT | 0 |
| HEAT LOSS CORRIDOR | — |
| UNHEATED CORRIDOR LENGTH | — |
| FLOOR HEIGHT | 2.4 |
| PHOTO SUPPLY | — |
| SOLAR WATER HEATING FLAG | N |
| MECHANICAL VENTILATION | natural |
| ADDRESS | 50, Oakside, Denham |
| LOCAL AUTHORITY LABEL | Buckinghamshire |
| CONSTITUENCY LABEL | Beaconsfield |
| POSTTOWN | UXBRIDGE |
| CONSTRUCTION AGE BAND | England and Wales: 1991-1995 |
| LODGEMENT DATETIME | 2013-06-14 00:23:55 |
| TENURE | Rented (social) |
| FIXED LIGHTING OUTLETS COUNT | 8 |
| LOW ENERGY FIXED LIGHT COUNT | 2 |
| UPRN | 100080497431 |
| UPRN SOURCE | Energy Assessor |
| REPORT TYPE | 2 |
| Source file | certificates-2013.csv |
| COUNTRY | England |
| REGION | E12000008 |
| Address display | — |
| Nation | ew |