Energy Performance Certificate

25, Alexandra Road, BA2 4PW

EPC Report

Energy rating

Current: 51 E | Potential: 73 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 51 E Current: 51 E 73 C Potential: 73 C

Environmental impact (CO₂)

Current: 54 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 77 Potential: 77
Field Value
LMK KEY 0807-2845-7879-9627-8361
ADDRESS1 25, Alexandra Road
ADDRESS2
ADDRESS3
POSTCODE BA2 4PW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 51
POTENTIAL ENERGY EFFICIENCY 73
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2013-03-25
LOCAL AUTHORITY E06000022
CONSTITUENCY E14001080
COUNTY
LODGEMENT DATE 2013-03-31
TRANSACTION TYPE Assessment for Green Deal
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 293
ENERGY CONSUMPTION POTENTIAL 147
CO2 EMISSIONS CURRENT 4.5
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 2.1
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 961
HEATING COST POTENTIAL 708
HOT WATER COST CURRENT 96
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 96
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 75
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 50
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 50% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 25, Alexandra Road
LOCAL AUTHORITY LABEL Bath and North East Somerset
CONSTITUENCY LABEL Bath
POSTTOWN BATH
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-03-31 15:16:02
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 12
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100120000347
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000009
Address display
Nation ew