Energy Performance Certificate

62, Farm Drive, SA12 6TF

EPC Report

Energy rating

Current: 35 F | Potential: 68 D
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 68 D Potential: 68 D

Environmental impact (CO₂)

Current: 32 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 63 Potential: 63
Field Value
LMK KEY 0807-2800-7495-9424-9475
ADDRESS1 62, Farm Drive
ADDRESS2
ADDRESS3
POSTCODE SA12 6TF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING D
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 68
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2014-01-20
LOCAL AUTHORITY W06000012
CONSTITUENCY W07000081
COUNTY
LODGEMENT DATE 2014-01-20
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 434
ENERGY CONSUMPTION POTENTIAL 189
CO2 EMISSIONS CURRENT 7.3
CO2 EMISS CURR PER FLOOR AREA 84
CO2 EMISSIONS POTENTIAL 3.2
LIGHTING COST CURRENT 104
LIGHTING COST POTENTIAL 52
HEATING COST CURRENT 941
HEATING COST POTENTIAL 786
HOT WATER COST CURRENT 512
HOT WATER COST POTENTIAL 113
TOTAL FLOOR AREA 87
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No time or thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 6
LOW ENERGY LIGHTING 0
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION System built, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 75 mm loft insulation
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION No time or thermostatic control of room temperature
MAINHEATC ENERGY EFF Very Poor
MAINHEATC ENV EFF Very Poor
LIGHTING DESCRIPTION No low energy lighting
LIGHTING ENERGY EFF Very Poor
LIGHTING ENV EFF Very Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.43
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 62, Farm Drive
LOCAL AUTHORITY LABEL Neath Port Talbot
CONSTITUENCY LABEL Aberafan Maesteg
POSTTOWN PORT TALBOT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-01-20 14:32:11
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 0
UPRN 100100632744
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY Wales
REGION W99999999
Address display
Nation ew