Energy Performance Certificate

41 Queen's Gate, SW7 5HR

EPC Report

Energy rating

Current: 65 D | Potential: 71 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 65 D Current: 65 D 71 C Potential: 71 C

Environmental impact (CO₂)

Current: 56 | Potential: 63
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 56 Current: 56 63 Potential: 63
Field Value
LMK KEY 0807-2729-1710-2199-0296
ADDRESS1 41 Queen's Gate
ADDRESS2
ADDRESS3
POSTCODE SW7 5HR
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 65
POTENTIAL ENERGY EFFICIENCY 71
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2023-01-11
LOCAL AUTHORITY E09000020
CONSTITUENCY E14001310
COUNTY
LODGEMENT DATE 2023-01-12
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 56
ENVIRONMENT IMPACT POTENTIAL 63
ENERGY CONSUMPTION CURRENT 143
ENERGY CONSUMPTION POTENTIAL 114
CO2 EMISSIONS CURRENT 30
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 24
LIGHTING COST CURRENT 363
LIGHTING COST POTENTIAL 363
HEATING COST CURRENT 6301
HEATING COST POTENTIAL 5207
HOT WATER COST CURRENT 151
HOT WATER COST POTENTIAL 151
TOTAL FLOOR AREA 1212
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 7
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 16
NUMBER HEATED ROOMS 11
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, insulated
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Portable electric heaters (assumed)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated at rafters
ROOF ENERGY EFF Average
ROOF ENV EFF Average
MAINHEAT DESCRIPTION Boiler and underfloor heating, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 41 Queen's Gate
LOCAL AUTHORITY LABEL Kensington and Chelsea
CONSTITUENCY LABEL Kensington and Bayswater
POSTTOWN LONDON
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2023-01-12 08:39:50
TENURE rented (private)
FIXED LIGHTING OUTLETS COUNT 40
LOW ENERGY FIXED LIGHT COUNT 40
UPRN 217071120
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2023.csv
COUNTRY England
REGION E12000007
Address display
Nation ew