Energy Performance Certificate

12, Elder Drive, BL3 1AT

EPC Report

Energy rating

Current: 61 D | Potential: 88 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 D Current: 61 D 88 B Potential: 88 B

Environmental impact (CO₂)

Current: 54 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 Current: 54 87 Potential: 87
Field Value
LMK KEY 0806-2843-7392-9195-9071
ADDRESS1 12, Elder Drive
ADDRESS2
ADDRESS3
POSTCODE BL3 1AT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 61
POTENTIAL ENERGY EFFICIENCY 88
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2015-01-17
LOCAL AUTHORITY E08000001
CONSTITUENCY E14001110
COUNTY
LODGEMENT DATE 2015-01-22
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 54
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 290
ENERGY CONSUMPTION POTENTIAL 83
CO2 EMISSIONS CURRENT 4.6
CO2 EMISS CURR PER FLOOR AREA 51
CO2 EMISSIONS POTENTIAL 1.4
LIGHTING COST CURRENT 97
LIGHTING COST POTENTIAL 60
HEATING COST CURRENT 655
HEATING COST POTENTIAL 435
HOT WATER COST CURRENT 294
HOT WATER COST POTENTIAL 68
TOTAL FLOOR AREA 91
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 38
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, insulated (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, as built, no insulation (assumed)
WALLS ENERGY EFF Poor
WALLS ENV EFF Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 150 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in 38% of fixed outlets
LIGHTING ENERGY EFF Average
LIGHTING ENV EFF Average
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.4
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 12, Elder Drive
LOCAL AUTHORITY LABEL Bolton
CONSTITUENCY LABEL Bolton North East
POSTTOWN BOLTON
CONSTRUCTION AGE BAND England and Wales: 2007-2011
LODGEMENT DATETIME 2015-01-22 14:05:19
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 5
UPRN 10001241416
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000002
Address display
Nation ew