Energy Performance Certificate

14 Fallow Drive, NR16 2FJ

EPC Report

Energy rating

Current: 86 B | Potential: 109 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 86 B Current: 86 B 109 A Potential: 109 A

Environmental impact (CO₂)

Current: 87 | Potential: 108
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 87 Current: 87 108 Potential: 108
Field Value
LMK KEY 0800-7845-0032-1224-3373
ADDRESS1 14 Fallow Drive
ADDRESS2
ADDRESS3
POSTCODE NR16 2FJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING B
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 86
POTENTIAL ENERGY EFFICIENCY 109
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2023-07-24
LOCAL AUTHORITY E07000143
CONSTITUENCY E14001365
COUNTY
LODGEMENT DATE 2023-07-24
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 87
ENVIRONMENT IMPACT POTENTIAL 108
ENERGY CONSUMPTION CURRENT 72
ENERGY CONSUMPTION POTENTIAL -50
CO2 EMISSIONS CURRENT 1.7
CO2 EMISS CURR PER FLOOR AREA 12
CO2 EMISSIONS POTENTIAL -1.2
LIGHTING COST CURRENT 192
LIGHTING COST POTENTIAL 192
HEATING COST CURRENT 733
HEATING COST POTENTIAL 734
HOT WATER COST CURRENT 311
HOT WATER COST POTENTIAL 193
TOTAL FLOOR AREA 143
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Very Good
FLOOR DESCRIPTION Average thermal transmittance 0.17 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.24 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.12 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 14 Fallow Drive
LOCAL AUTHORITY LABEL Breckland
CONSTITUENCY LABEL Mid Norfolk
POSTTOWN BANHAM
CONSTRUCTION AGE BAND 2023
LODGEMENT DATETIME 2023-07-24 14:48:52
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 10096178663
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2023.csv
COUNTRY England
REGION E12000006
Address display
Nation ew