Energy Performance Certificate

Flat 12, 4 Kingsbury Avenue, Manston, CT12 5NG

EPC Report

Energy rating

Current: 79 C | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 79 C Current: 79 C 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 81 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 81 Current: 81 81 Potential: 81
Field Value
LMK KEY 0800-2873-0332-2023-3153
ADDRESS1 Flat 12
ADDRESS2 4 Kingsbury Avenue
ADDRESS3 Manston
POSTCODE CT12 5NG
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 79
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE Flat
BUILT FORM Mid-Terrace
INSPECTION DATE 2025-09-23
LOCAL AUTHORITY E07000114
CONSTITUENCY E14001282
COUNTY
LODGEMENT DATE 2025-09-23
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 81
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 154
ENERGY CONSUMPTION POTENTIAL 154
CO2 EMISSIONS CURRENT 1.3
CO2 EMISS CURR PER FLOOR AREA 26
CO2 EMISSIONS POTENTIAL 1.3
LIGHTING COST CURRENT 63
LIGHTING COST POTENTIAL 63
HEATING COST CURRENT 228
HEATING COST POTENTIAL 228
HOT WATER COST CURRENT 371
HOT WATER COST POTENTIAL 371
TOTAL FLOOR AREA 51
ENERGY TARIFF standard tariff
MAINS GAS FLAG
FLOOR LEVEL 3
FLAT TOP STOREY Y
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Electric immersion, standard tariff
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION (other premises below)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.21 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, warm air, electric
MAINHEAT ENERGY EFF Poor
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.55
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS Flat 12, 4 Kingsbury Avenue, Manston
LOCAL AUTHORITY LABEL Thanet
CONSTITUENCY LABEL Herne Bay and Sandwich
POSTTOWN Ramsgate
CONSTRUCTION AGE BAND 2024
LODGEMENT DATETIME 2025-09-23 14:54:32
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 10097162433
UPRN SOURCE Address Matched
REPORT TYPE 3
Source file certificates-2025.csv
COUNTRY England
REGION E12000008
Address display
Nation ew