Energy Performance Certificate

14, Bianca Street, L20 7DT

EPC Report

Energy rating

Current: 63 D | Potential: 86 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 86 B Potential: 86 B

Environmental impact (CO₂)

Current: 61 | Potential: 87
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 61 Current: 61 87 Potential: 87
Field Value
LMK KEY 0800-2853-7076-9523-3005
ADDRESS1 14, Bianca Street
ADDRESS2
ADDRESS3
POSTCODE L20 7DT
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 86
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2017-03-27
LOCAL AUTHORITY E08000014
CONSTITUENCY E14001113
COUNTY
LODGEMENT DATE 2017-03-27
TRANSACTION TYPE Rental
ENVIRONMENT IMPACT CURRENT 61
ENVIRONMENT IMPACT POTENTIAL 87
ENERGY CONSUMPTION CURRENT 260
ENERGY CONSUMPTION POTENTIAL 75
CO2 EMISSIONS CURRENT 3
CO2 EMISS CURR PER FLOOR AREA 45
CO2 EMISSIONS POTENTIAL 0.9
LIGHTING COST CURRENT 46
LIGHTING COST POTENTIAL 46
HEATING COST CURRENT 601
HEATING COST POTENTIAL 390
HOT WATER COST CURRENT 99
HOT WATER COST POTENTIAL 67
TOTAL FLOOR AREA 66
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.67
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 14, Bianca Street
LOCAL AUTHORITY LABEL Sefton
CONSTITUENCY LABEL Bootle
POSTTOWN BOOTLE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2017-03-27 20:58:06
TENURE rented (social)
FIXED LIGHTING OUTLETS COUNT 10
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 41007848
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2017.csv
COUNTRY England
REGION E12000002
Address display
Nation ew