Energy Performance Certificate

31, Exeter Road, DN15 7AU

EPC Report

Energy rating

Current: 54 E | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 54 E Current: 54 E 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 46 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 46 Current: 46 68 Potential: 68
Field Value
LMK KEY 0798-1079-6202-7786-0974
ADDRESS1 31, Exeter Road
ADDRESS2
ADDRESS3
POSTCODE DN15 7AU
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 54
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2016-02-01
LOCAL AUTHORITY E06000013
CONSTITUENCY E14001462
COUNTY
LODGEMENT DATE 2016-02-02
TRANSACTION TYPE ECO assessment
ENVIRONMENT IMPACT CURRENT 46
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 360
ENERGY CONSUMPTION POTENTIAL 204
CO2 EMISSIONS CURRENT 5.4
CO2 EMISS CURR PER FLOOR AREA 64
CO2 EMISSIONS POTENTIAL 3.1
LIGHTING COST CURRENT 66
LIGHTING COST POTENTIAL 66
HEATING COST CURRENT 792
HEATING COST POTENTIAL 751
HOT WATER COST CURRENT 345
HOT WATER COST POTENTIAL 112
TOTAL FLOOR AREA 85
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 80
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas boiler/circulator, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.46
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 31, Exeter Road
LOCAL AUTHORITY LABEL North Lincolnshire
CONSTITUENCY LABEL Scunthorpe
POSTTOWN SCUNTHORPE
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2016-02-02 14:32:50
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100050205071
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2016.csv
COUNTRY England
REGION E12000003
Address display
Nation ew