Energy Performance Certificate

3, Dover Drive, CH65 9EP

EPC Report

Energy rating

Current: 80 C | Potential: 90 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 90 B Potential: 90 B

Environmental impact (CO₂)

Current: 77 | Potential: 91
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 77 Current: 77 91 Potential: 91
Field Value
LMK KEY 0794-2806-6184-9124-7995
ADDRESS1 3, Dover Drive
ADDRESS2
ADDRESS3
POSTCODE CH65 9EP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 90
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2014-08-26
LOCAL AUTHORITY E06000050
CONSTITUENCY E14001222
COUNTY
LODGEMENT DATE 2014-08-26
TRANSACTION TYPE FiT application
ENVIRONMENT IMPACT CURRENT 77
ENVIRONMENT IMPACT POTENTIAL 91
ENERGY CONSUMPTION CURRENT 125
ENERGY CONSUMPTION POTENTIAL 48
CO2 EMISSIONS CURRENT 2.4
CO2 EMISS CURR PER FLOOR AREA 25
CO2 EMISSIONS POTENTIAL 1.0
LIGHTING COST CURRENT 81
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 612
HEATING COST POTENTIAL 425
HOT WATER COST CURRENT 174
HOT WATER COST POTENTIAL 83
TOTAL FLOOR AREA 98
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 61
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 250 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Average
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 61% of fixed outlets
LIGHTING ENERGY EFF Good
LIGHTING ENV EFF Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Dover Drive
LOCAL AUTHORITY LABEL Cheshire West and Chester
CONSTITUENCY LABEL Ellesmere Port and Bromborough
POSTTOWN ELLESMERE PORT
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2014-08-26 21:32:39
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 18
LOW ENERGY FIXED LIGHT COUNT 11
UPRN 100010109567
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000002
Address display
Nation ew