Energy Performance Certificate

2, Newark Close, Ripley, GU23 6DW

EPC Report

Energy rating

Current: 66 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 66 D Current: 66 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 64 | Potential: 81
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 64 Current: 64 81 Potential: 81
Field Value
LMK KEY 0789-2841-6930-2620-2855
ADDRESS1 2, Newark Close
ADDRESS2 Ripley
ADDRESS3
POSTCODE GU23 6DW
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 66
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2020-07-29
LOCAL AUTHORITY E07000209
CONSTITUENCY E14001258
COUNTY
LODGEMENT DATE 2020-07-31
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 64
ENVIRONMENT IMPACT POTENTIAL 81
ENERGY CONSUMPTION CURRENT 201
ENERGY CONSUMPTION POTENTIAL 100
CO2 EMISSIONS CURRENT 4.8
CO2 EMISS CURR PER FLOOR AREA 32
CO2 EMISSIONS POTENTIAL 2.4
LIGHTING COST CURRENT 98
LIGHTING COST POTENTIAL 98
HEATING COST CURRENT 959
HEATING COST POTENTIAL 635
HOT WATER COST CURRENT 106
HOT WATER COST POTENTIAL 107
TOTAL FLOOR AREA 150
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Programmer, room thermostat and TRVs
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 3
NUMBER HABITABLE ROOMS 7
NUMBER HEATED ROOMS 7
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, wood logs
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, insulated (assumed)
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, room thermostat and TRVs
MAINHEATC ENERGY EFF Good
MAINHEATC ENV EFF Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.41
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 2, Newark Close, Ripley
LOCAL AUTHORITY LABEL Guildford
CONSTITUENCY LABEL Guildford
POSTTOWN WOKING
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2020-07-31 09:02:01
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 35
LOW ENERGY FIXED LIGHT COUNT 35
UPRN 100061412948
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000008
Address display
Nation ew