Energy Performance Certificate

The Old Dolphin, 36 Cecily Hill, GL7 2EF

EPC Report

Energy rating

Current: 38 F | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 38 F Current: 38 F 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 29 | Potential: 65
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 29 Current: 29 65 Potential: 65
Field Value
LMK KEY 0788-2003-7206-3565-6944
ADDRESS1 The Old Dolphin
ADDRESS2 36 Cecily Hill
ADDRESS3
POSTCODE GL7 2EF
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 38
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2015-06-08
LOCAL AUTHORITY E07000079
CONSTITUENCY E14001482
COUNTY
LODGEMENT DATE 2015-06-08
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 29
ENVIRONMENT IMPACT POTENTIAL 65
ENERGY CONSUMPTION CURRENT 401
ENERGY CONSUMPTION POTENTIAL 166
CO2 EMISSIONS CURRENT 19
CO2 EMISS CURR PER FLOOR AREA 71
CO2 EMISSIONS POTENTIAL 8.0
LIGHTING COST CURRENT 198
LIGHTING COST POTENTIAL 108
HEATING COST CURRENT 3433
HEATING COST POTENTIAL 1641
HOT WATER COST CURRENT 280
HOT WATER COST POTENTIAL 137
TOTAL FLOOR AREA 272
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 48
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 4
NUMBER HABITABLE ROOMS 8
NUMBER HEATED ROOMS 8
LOW ENERGY LIGHTING 14
NUMBER OPEN FIREPLACES 1
HOTWATER DESCRIPTION From main system, no cylinder thermostat
HOT WATER ENERGY EFF Poor
HOT WATER ENV EFF Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Partial double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Sandstone or limestone, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, limited insulation (assumed)
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.27
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS The Old Dolphin, 36 Cecily Hill
LOCAL AUTHORITY LABEL Cotswold
CONSTITUENCY LABEL South Cotswolds
POSTTOWN CIRENCESTER
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2015-06-08 12:46:08
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 43
LOW ENERGY FIXED LIGHT COUNT 6
UPRN 100121238273
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2015.csv
COUNTRY England
REGION E12000009
Address display
Nation ew