Energy Performance Certificate

96, Station Road, Filton, BS34 7JJ

EPC Report

Energy rating

Current: 43 E | Potential: 79 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 43 E Current: 43 E 79 C Potential: 79 C

Environmental impact (CO₂)

Current: 39 | Potential: 76
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 39 Current: 39 76 Potential: 76
Field Value
LMK KEY 0768-9074-7269-1374-9900
ADDRESS1 96, Station Road
ADDRESS2 Filton
ADDRESS3
POSTCODE BS34 7JJ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING E
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 43
POTENTIAL ENERGY EFFICIENCY 79
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2014-01-06
LOCAL AUTHORITY E06000025
CONSTITUENCY E14001237
COUNTY
LODGEMENT DATE 2014-01-06
TRANSACTION TYPE None of the above
ENVIRONMENT IMPACT CURRENT 39
ENVIRONMENT IMPACT POTENTIAL 76
ENERGY CONSUMPTION CURRENT 342
ENERGY CONSUMPTION POTENTIAL 112
CO2 EMISSIONS CURRENT 6.9
CO2 EMISS CURR PER FLOOR AREA 66
CO2 EMISSIONS POTENTIAL 2.3
LIGHTING COST CURRENT 105
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1245
HEATING COST POTENTIAL 643
HOT WATER COST CURRENT 139
HOT WATER COST POTENTIAL 75
TOTAL FLOOR AREA 104
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer and room thermostat
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 22
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, no insulation (assumed)
ROOF ENERGY EFF Very Poor
ROOF ENV EFF Very Poor
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer and room thermostat
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 22% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.57
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 96, Station Road, Filton
LOCAL AUTHORITY LABEL South Gloucestershire
CONSTITUENCY LABEL Filton and Bradley Stoke
POSTTOWN BRISTOL
CONSTRUCTION AGE BAND England and Wales: 1930-1949
LODGEMENT DATETIME 2014-01-06 15:12:37
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 2
UPRN 509303
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2014.csv
COUNTRY England
REGION E12000009
Address display