Energy Performance Certificate

22, Linden Road, CT8 8BY

EPC Report

Energy rating

Current: 21 F | Potential: 50 E
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 21 F Current: 21 F 50 E Potential: 50 E

Environmental impact (CO₂)

Current: 32 | Potential: 57
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 Current: 32 57 Potential: 57
Field Value
LMK KEY 0768-7000-7232-5768-2994
ADDRESS1 22, Linden Road
ADDRESS2
ADDRESS3
POSTCODE CT8 8BY
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING E
CURRENT ENERGY EFFICIENCY 21
POTENTIAL ENERGY EFFICIENCY 50
PROPERTY TYPE House
BUILT FORM Mid-Terrace
INSPECTION DATE 2018-02-06
LOCAL AUTHORITY E07000114
CONSTITUENCY E14001282
COUNTY
LODGEMENT DATE 2018-02-06
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 32
ENVIRONMENT IMPACT POTENTIAL 57
ENERGY CONSUMPTION CURRENT 469
ENERGY CONSUMPTION POTENTIAL 250
CO2 EMISSIONS CURRENT 8.3
CO2 EMISS CURR PER FLOOR AREA 82
CO2 EMISSIONS POTENTIAL 4.5
LIGHTING COST CURRENT 79
LIGHTING COST POTENTIAL 79
HEATING COST CURRENT 2297
HEATING COST POTENTIAL 1546
HOT WATER COST CURRENT 102
HOT WATER COST POTENTIAL 56
TOTAL FLOOR AREA 101
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 100
GLAZED TYPE double glazing installed during or after 2002
GLAZED AREA Normal
EXTENSION COUNT 1
NUMBER HABITABLE ROOMS 6
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 82
NUMBER OPEN FIREPLACES 3
HOTWATER DESCRIPTION Gas multipoint
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Good
WINDOWS ENV EFF Good
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, dual fuel (mineral and wood)
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 50 mm loft insulation
ROOF ENERGY EFF Poor
ROOF ENV EFF Poor
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 82% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL dual fuel - mineral + wood
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.68
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 22, Linden Road
LOCAL AUTHORITY LABEL Thanet
CONSTITUENCY LABEL Herne Bay and Sandwich
POSTTOWN WESTGATE-ON-SEA
CONSTRUCTION AGE BAND England and Wales: 1900-1929
LODGEMENT DATETIME 2018-02-06 17:45:42
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 11
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 100061148027
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000008
Address display
Nation ew