Energy Performance Certificate

6 Melton Close, Astley, Tyldesley, M29 7PP

EPC Report

Energy rating

Current: 63 D | Potential: 82 B
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 63 D Current: 63 D 82 B Potential: 82 B

Environmental impact (CO₂)

Current: 59 | Potential: 74
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 59 Current: 59 74 Potential: 74
Field Value
LMK KEY 0767-1201-3305-3075-1600
ADDRESS1 6 Melton Close
ADDRESS2 Astley
ADDRESS3 Tyldesley
POSTCODE M29 7PP
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING B
CURRENT ENERGY EFFICIENCY 63
POTENTIAL ENERGY EFFICIENCY 82
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2025-06-30
LOCAL AUTHORITY E08000010
CONSTITUENCY E14001329
COUNTY
LODGEMENT DATE 2025-06-30
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 59
ENVIRONMENT IMPACT POTENTIAL 74
ENERGY CONSUMPTION CURRENT 243
ENERGY CONSUMPTION POTENTIAL 152
CO2 EMISSIONS CURRENT 3.9
CO2 EMISS CURR PER FLOOR AREA 44
CO2 EMISSIONS POTENTIAL 2.5
LIGHTING COST CURRENT 85
LIGHTING COST POTENTIAL 57
HEATING COST CURRENT 956
HEATING COST POTENTIAL 708
HOT WATER COST CURRENT 193
HOT WATER COST POTENTIAL 133
TOTAL FLOOR AREA 87
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 5
NUMBER HEATED ROOMS 5
LOW ENERGY LIGHTING 63
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, as built, insulated (assumed)
WALLS ENERGY EFF Good
WALLS ENV EFF Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 300 mm loft insulation
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Below average lighting efficiency
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.31
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 6 Melton Close, Astley, Tyldesley
LOCAL AUTHORITY LABEL Wigan
CONSTITUENCY LABEL Leigh and Atherton
POSTTOWN MANCHESTER
CONSTRUCTION AGE BAND England and Wales: 1983-1990
LODGEMENT DATETIME 2025-06-30 17:35:39
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 30
LOW ENERGY FIXED LIGHT COUNT 19
UPRN 100011733765
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2025.csv
COUNTRY England
REGION E12000002
Address display
Nation ew