Energy Performance Certificate

27, Coopers Close, High Hesket, CA4 0JD

EPC Report

Energy rating

Current: 80 C | Potential: 105 A
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 80 C Current: 80 C 105 A Potential: 105 A

Environmental impact (CO₂)

Current: 83 | Potential: 105
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 83 Current: 83 105 Potential: 105
Field Value
LMK KEY 0766-3873-7429-2620-0331
ADDRESS1 27, Coopers Close
ADDRESS2 High Hesket
ADDRESS3
POSTCODE CA4 0JD
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING C
POTENTIAL ENERGY RATING A
CURRENT ENERGY EFFICIENCY 80
POTENTIAL ENERGY EFFICIENCY 105
PROPERTY TYPE Bungalow
BUILT FORM Detached
INSPECTION DATE 2020-02-27
LOCAL AUTHORITY E06000064
CONSTITUENCY E14001424
COUNTY
LODGEMENT DATE 2020-02-27
TRANSACTION TYPE New dwelling
ENVIRONMENT IMPACT CURRENT 83
ENVIRONMENT IMPACT POTENTIAL 105
ENERGY CONSUMPTION CURRENT 103
ENERGY CONSUMPTION POTENTIAL -28
CO2 EMISSIONS CURRENT 2.3
CO2 EMISS CURR PER FLOOR AREA 17
CO2 EMISSIONS POTENTIAL -0.6
LIGHTING COST CURRENT 84
LIGHTING COST POTENTIAL 84
HEATING COST CURRENT 509
HEATING COST POTENTIAL 509
HOT WATER COST CURRENT 184
HOT WATER COST POTENTIAL 111
TOTAL FLOOR AREA 134
ENERGY TARIFF off-peak 10 hour
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 1
MAIN HEATING CONTROLS Time and temperature zone control
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT
NUMBER HABITABLE ROOMS
NUMBER HEATED ROOMS
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Average thermal transmittance 0.15 W/m²K
FLOOR ENERGY EFF Very Good
FLOOR ENV EFF Very Good
WINDOWS DESCRIPTION High performance glazing
WINDOWS ENERGY EFF Very Good
WINDOWS ENV EFF Very Good
WALLS DESCRIPTION Average thermal transmittance 0.21 W/m²K
WALLS ENERGY EFF Very Good
WALLS ENV EFF Very Good
SECONDHEAT DESCRIPTION None
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Average thermal transmittance 0.11 W/m²K
ROOF ENERGY EFF Very Good
ROOF ENV EFF Very Good
MAINHEAT DESCRIPTION Air source heat pump, underfloor, electric
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Very Good
MAINHEATCONT DESCRIPTION Time and temperature zone control
MAINHEATC ENERGY EFF Very Good
MAINHEATC ENV EFF Very Good
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL Electricity: electricity, unspecified tariff
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.5
PHOTO SUPPLY
SOLAR WATER HEATING FLAG
MECHANICAL VENTILATION
ADDRESS 27, Coopers Close, High Hesket
LOCAL AUTHORITY LABEL Westmorland and Furness
CONSTITUENCY LABEL Penrith and Solway
POSTTOWN CARLISLE
CONSTRUCTION AGE BAND 2019
LODGEMENT DATETIME 2020-02-27 15:48:13
TENURE unknown
FIXED LIGHTING OUTLETS COUNT 20
LOW ENERGY FIXED LIGHT COUNT 20
UPRN 10070543527
UPRN SOURCE Energy Assessor
REPORT TYPE 3
Source file certificates-2020.csv
COUNTRY England
REGION E12000002
Address display
Nation ew