Energy Performance Certificate

46, Birkin Avenue, Radcliffe-on-Trent, NG12 1DQ

EPC Report

Energy rating

Current: 32 F | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 32 F Current: 32 F 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 37 | Potential: 77
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 37 Current: 37 77 Potential: 77
Field Value
LMK KEY 0765-2885-7794-2590-6811
ADDRESS1 46, Birkin Avenue
ADDRESS2 Radcliffe-on-Trent
ADDRESS3
POSTCODE NG12 1DQ
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 32
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM End-Terrace
INSPECTION DATE 2020-01-15
LOCAL AUTHORITY E07000176
CONSTITUENCY E14001457
COUNTY
LODGEMENT DATE 2020-01-15
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 37
ENVIRONMENT IMPACT POTENTIAL 77
ENERGY CONSUMPTION CURRENT 465
ENERGY CONSUMPTION POTENTIAL 144
CO2 EMISSIONS CURRENT 5.9
CO2 EMISS CURR PER FLOOR AREA 80
CO2 EMISSIONS POTENTIAL 1.8
LIGHTING COST CURRENT 59
LIGHTING COST POTENTIAL 59
HEATING COST CURRENT 1175
HEATING COST POTENTIAL 754
HOT WATER COST CURRENT 443
HOT WATER COST POTENTIAL 71
TOTAL FLOOR AREA 73
ENERGY TARIFF Single
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS No thermostatic control of room temperature
MULTI GLAZE PROPORTION 20
GLAZED TYPE double glazing, unknown install date
GLAZED AREA Normal
EXTENSION COUNT 0
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 1
LOW ENERGY LIGHTING 100
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION Gas boiler/circulator, no cylinder thermostat
HOT WATER ENERGY EFF Very Poor
HOT WATER ENV EFF Very Poor
FLOOR DESCRIPTION Solid, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Some double glazing
WINDOWS ENERGY EFF Poor
WINDOWS ENV EFF Poor
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Portable electric heaters assumed for most rooms, Room heaters, electric
MAINHEAT ENERGY EFF Very Poor
MAINHEAT ENV EFF Poor
MAINHEATCONT DESCRIPTION No thermostatic control of room temperature
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in all fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.39
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 46, Birkin Avenue, Radcliffe-on-Trent
LOCAL AUTHORITY LABEL Rushcliffe
CONSTITUENCY LABEL Rushcliffe
POSTTOWN NOTTINGHAM
CONSTRUCTION AGE BAND England and Wales: 1967-1975
LODGEMENT DATETIME 2020-01-15 15:53:49
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 9
LOW ENERGY FIXED LIGHT COUNT 9
UPRN 3040036280
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2020.csv
COUNTRY England
REGION E12000004
Address display
Nation ew