Energy Performance Certificate

33, Apple Tree Road, WR10 1ER

EPC Report

Energy rating

Current: 58 D | Potential: 80 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 58 D Current: 58 D 80 C Potential: 80 C

Environmental impact (CO₂)

Current: 55 | Potential: 78
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 55 Current: 55 78 Potential: 78
Field Value
LMK KEY 0764-2803-7516-9528-0411
ADDRESS1 33, Apple Tree Road
ADDRESS2
ADDRESS3
POSTCODE WR10 1ER
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING D
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 58
POTENTIAL ENERGY EFFICIENCY 80
PROPERTY TYPE House
BUILT FORM Semi-Detached
INSPECTION DATE 2018-09-27
LOCAL AUTHORITY E07000238
CONSTITUENCY E14001579
COUNTY
LODGEMENT DATE 2018-09-28
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 55
ENVIRONMENT IMPACT POTENTIAL 78
ENERGY CONSUMPTION CURRENT 269
ENERGY CONSUMPTION POTENTIAL 119
CO2 EMISSIONS CURRENT 4.3
CO2 EMISS CURR PER FLOOR AREA 47
CO2 EMISSIONS POTENTIAL 1.9
LIGHTING COST CURRENT 78
LIGHTING COST POTENTIAL 78
HEATING COST CURRENT 836
HEATING COST POTENTIAL 581
HOT WATER COST CURRENT 87
HOT WATER COST POTENTIAL 57
TOTAL FLOOR AREA 91
ENERGY TARIFF Unknown
MAINS GAS FLAG Y
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Room thermostat only
MULTI GLAZE PROPORTION 91
GLAZED TYPE double glazing installed before 2002
GLAZED AREA Normal
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 4
NUMBER HEATED ROOMS 4
LOW ENERGY LIGHTING 77
NUMBER OPEN FIREPLACES 0
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Good
HOT WATER ENV EFF Good
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Mostly double glazing
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Cavity wall, filled cavity
WALLS ENERGY EFF Average
WALLS ENV EFF Average
SECONDHEAT DESCRIPTION Room heaters, electric
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Room thermostat only
MAINHEATC ENERGY EFF Poor
MAINHEATC ENV EFF Poor
LIGHTING DESCRIPTION Low energy lighting in 77% of fixed outlets
LIGHTING ENERGY EFF Very Good
LIGHTING ENV EFF Very Good
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 2.35
PHOTO SUPPLY 0
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 33, Apple Tree Road
LOCAL AUTHORITY LABEL Wychavon
CONSTITUENCY LABEL West Worcestershire
POSTTOWN PERSHORE
CONSTRUCTION AGE BAND England and Wales: 1950-1966
LODGEMENT DATETIME 2018-09-28 10:46:55
TENURE owner-occupied
FIXED LIGHTING OUTLETS COUNT 13
LOW ENERGY FIXED LIGHT COUNT 10
UPRN 100120699919
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2018.csv
COUNTRY England
REGION E12000005
Address display
Nation ew