Energy Performance Certificate

3, Squires Walk, WS10 9DB

EPC Report

Energy rating

Current: 35 F | Potential: 74 C
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 35 F Current: 35 F 74 C Potential: 74 C

Environmental impact (CO₂)

Current: 30 | Potential: 68
Current Potential A 92–100 B 81–91 C 69–80 D 55–68 E 39–54 F 21–38 G 1–20 30 Current: 30 68 Potential: 68
Field Value
LMK KEY 0762-2879-6236-9977-3985
ADDRESS1 3, Squires Walk
ADDRESS2
ADDRESS3
POSTCODE WS10 9DB
BUILDING REFERENCE NUMBER
CURRENT ENERGY RATING F
POTENTIAL ENERGY RATING C
CURRENT ENERGY EFFICIENCY 35
POTENTIAL ENERGY EFFICIENCY 74
PROPERTY TYPE House
BUILT FORM Detached
INSPECTION DATE 2013-07-31
LOCAL AUTHORITY E08000028
CONSTITUENCY E14001547
COUNTY
LODGEMENT DATE 2013-07-31
TRANSACTION TYPE Marketed sale
ENVIRONMENT IMPACT CURRENT 30
ENVIRONMENT IMPACT POTENTIAL 68
ENERGY CONSUMPTION CURRENT 368
ENERGY CONSUMPTION POTENTIAL 141
CO2 EMISSIONS CURRENT 16
CO2 EMISS CURR PER FLOOR AREA 71
CO2 EMISSIONS POTENTIAL 6.3
LIGHTING COST CURRENT 168
LIGHTING COST POTENTIAL 90
HEATING COST CURRENT 2846
HEATING COST POTENTIAL 1276
HOT WATER COST CURRENT 180
HOT WATER COST POTENTIAL 120
TOTAL FLOOR AREA 231
ENERGY TARIFF Single
MAINS GAS FLAG
FLOOR LEVEL
FLAT TOP STOREY N
FLAT STOREY COUNT 2
MAIN HEATING CONTROLS Programmer, TRVs and bypass
MULTI GLAZE PROPORTION 100
GLAZED TYPE
GLAZED AREA
EXTENSION COUNT 2
NUMBER HABITABLE ROOMS 10
NUMBER HEATED ROOMS 10
LOW ENERGY LIGHTING 14
NUMBER OPEN FIREPLACES 4
HOTWATER DESCRIPTION From main system
HOT WATER ENERGY EFF Average
HOT WATER ENV EFF Average
FLOOR DESCRIPTION Suspended, no insulation (assumed)
FLOOR ENERGY EFF N/A
FLOOR ENV EFF N/A
WINDOWS DESCRIPTION Fully double glazed
WINDOWS ENERGY EFF Average
WINDOWS ENV EFF Average
WALLS DESCRIPTION Solid brick, as built, no insulation (assumed)
WALLS ENERGY EFF Very Poor
WALLS ENV EFF Very Poor
SECONDHEAT DESCRIPTION Room heaters, mains gas
SHEATING ENERGY EFF N/A
SHEATING ENV EFF N/A
ROOF DESCRIPTION Pitched, 200 mm loft insulation
ROOF ENERGY EFF Good
ROOF ENV EFF Good
MAINHEAT DESCRIPTION Boiler and radiators, mains gas
MAINHEAT ENERGY EFF Good
MAINHEAT ENV EFF Good
MAINHEATCONT DESCRIPTION Programmer, TRVs and bypass
MAINHEATC ENERGY EFF Average
MAINHEATC ENV EFF Average
LIGHTING DESCRIPTION Low energy lighting in 14% of fixed outlets
LIGHTING ENERGY EFF Poor
LIGHTING ENV EFF Poor
MAIN FUEL mains gas (not community)
WIND TURBINE COUNT 0
HEAT LOSS CORRIDOR
UNHEATED CORRIDOR LENGTH
FLOOR HEIGHT 3.05
PHOTO SUPPLY
SOLAR WATER HEATING FLAG N
MECHANICAL VENTILATION natural
ADDRESS 3, Squires Walk
LOCAL AUTHORITY LABEL Sandwell
CONSTITUENCY LABEL Tipton and Wednesbury
POSTTOWN WEDNESBURY
CONSTRUCTION AGE BAND England and Wales: before 1900
LODGEMENT DATETIME 2013-07-31 16:20:37
TENURE Owner-occupied
FIXED LIGHTING OUTLETS COUNT 28
LOW ENERGY FIXED LIGHT COUNT 4
UPRN 32074728
UPRN SOURCE Energy Assessor
REPORT TYPE 2
Source file certificates-2013.csv
COUNTRY England
REGION E12000005
Address display
Nation ew